Future-automation PH Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 22
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
Page 14 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PH2 - Projector Hinge
Installation: Electrical Connection
Contact Closure
Use an RJ45 connector in the
CCI socket on the control box
to operate via contact closure
SLQV
LED 1
LED 2
LED 3
LED 4
LED 5
CONTACT CLOSURE INPUT
NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.
568A 568B
1 12V SUPPLY
12V SUPPLY - CURRENT LIMITED
W/G W/O
2 12V LATCH
When 12V attached, device will go OUT. When
12V removed, device will go IN.
GO
3GROUND GROUND W/OW/G
4 DEVICE LATCH
Short to GROUND (pin 3), device will go OUT,
remove short device will go IN.
BL BL N / A
5 PIN 4 NOT USED W/BL W/BL N / A
6 DEVICE STOP
Momentary short to GROUND (pin 3), stops
device in current position.
O G N / A
7 DEVICE OUT
Momentary short to GROUND (pin 3), makes
device go OUT.
W/BR W/BR N / A
8 DEVICE IN
Momentary short to GROUND (pin 3), makes
device go IN.
BR BR N / A
PIN DESCRIPTION ACTION
WIRE / CABLE
CONTACT CLOSURE
LED INDICATOR
Vista de página 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 21 22

Comentários a estes Manuais

Sem comentários