PROTOCOL ACTION
fa_in Carriage Return (Enter ) Device IN
fa_out Carriage Return (Enter ) Beam OUT no movement to swivel
fa_right Carriage Return (Enter ) Device OUT RIGHT limit
fa_left Carriage Return (Enter ) Device OUT LEFT limit
fa_preset Carriage Return (Enter ) Device to PRESET memory position
fa_a Carriage Return (Enter ) Device OUT to memory position a
fa_b Carriage Return (Enter ) Device OUT to memory position b
fa_c Carriage Return (Enter ) Device OUT to memory position c
fa_stop Carriage Return (Enter ) STOPS the device at any position
Installation: IR Control
Page 18 of 22 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PLS - Plasma Lift and Swivel
Operation Details
DC1
Low voltage power output for motor drive.
LED’s to show operation of limit switches
and positional counters
Mains Voltage Input
IR LED
IR Input Jack
RS232
Contact Closure
S
LQV
RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232
Details
Baud rate: 9600
Stop bit: 1
Parity: None
Databits: 8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND
Pin 2: TX
Pin 3: RX
Pin 5: GROUND
IMPORTANT
Ensure protocol is entered exactly as written, including Carriage Return (Enter / ASCII 13).
RJ25 9 PIN D
PIN 1: RX TO PIN 2: TX
PIN 6: TX TO PIN 3: RX
PIN 3: GROUND TO PIN 5: GROUND
PIN 4: GROUND TO PIN 5: GROUND